How The System Works
 
  Certification
   
   
   
   
   
   
   
   
   
   
   
   
 
Zapatec Javascript Menu

 

Atlas Incinerators
     
  Atlas 600 Series  
     
  Incinerator (model no.) 600 S WS 600 SL P 600 SL WS P
  Combustion Capacity (kW) 581 581 581
  Combustion Capacity (kcal/h) 500.000 500.000 500.000
  Combustion Capacity - Solid waste IMO spec. (kg/h) 100   100
  IMO spec.(l/charge)   250  
  Combustion Capacity - Sludge oil   66 66
  (max. l/h)   100 100
  Length L (mm) 2508 2044 2508
  Width (mm) 1806 1806 1806
  Height (mm) 2457 2457 2457
  Charging door opening (mm) 350*350 550*550 350*350
  Weight approx. (kg) 4850 4600 4850
   
  S = Solid waste L = Sludge/Liquid waste WS = Solid Waste Sluice P = PLC control unit
   
  Total air consumption incinerator: 5,200 Nm3/h
   
  Flue gas temp: 350oC
   
  Flue gas volume: 12,450 m3/h at 350oC
   
  Max. Counter pressure in funnel, incl. Outlet loss: 590 Pa (60 mm W.G.)
   
  Fuel oil consumption for heating the incinerator: approx. 34 litres

   
  Compressed air consumption sludge burner: max. 32 m3/h at 20oC
   
 

Sluice operation: max. 0.15 m3/h at 20oC

   
  Compressed air pressure: 7 - 10 bar

 

 

 