HOME
HISTORY
PRODUCTS
Sewage Treatment
Marine/Offshore Cranes
Oily Water Separators
Water Purification
Incinerators
Filtration
Hot Oil Heaters
RENTALS
CONTACTS
LOCATIONS
How The System Works
Certification
Zapatec Javascript Menu
Atlas Incinerators
Atlas 200 Series
Incinerator (model no.)
200 S WS
200 SL
200 SL WS
Combustion Capacity (kW)
209
209
209
Combustion Capacity (kcal/h)
180.000
180.000
180.000
Combustion Capacity - Solid waste IMO spec. (kg/h)
40
40
IMO spec.(l/charge)
150
Combustion Capacity - Sludge oil
24
24
(max. l/h)
40
40
Length L (mm)
1590
1550
1590
Width (mm)
1838
1490
1838
Height (mm)
2110
2110
2110
Charging door opening (mm)
350*350
512*916
350*350
Weight approx. (kg)
3175
3050
3175
S = Solid waste L = Sludge/Liquid waste WS = Solid Waste Sluice P = PLC control unit
Total air consumption incinerator: 3,100 Nm3/h
Flue gas temp: 250oC
Flue gas volume: 6,220 m3/h at 250oC Max.
Max. Counter pressure in funnel, incl. Outlet loss: 590 Pa (60 mm W.G.)
Fuel oil consumption for heating the incinerator: approx. 14 litres
Sluice operation: max. 0.15 m3/h at 20oC
Compressed air pressure: 7 - 10 bar
Compressed air consumption sludge burner: max. 5 m3/h at 20oC
Product Line
-
Atlas 200 Series
-
Atlas 600 Series
-
Atlas 800 Series
-
Atlas 1200 Series
© 2005 Green Marine - 1111 Central Ave, Metairie, LA 70001 (504) 833.7386